File IO
Specific Data Formats
The .m matpower files have been extended with the fields as described in the MatACDC manual, available in https://www.esat.kuleuven.be/electa/teaching/matacdc#documentation.
DC Bus
busdc_i
- DC bus numbergrid
- DC grid to which the DC bus is connected (in case multiple DC grids)Pdc
- Power withdrawn from the DC grid (MW) (only for PF)Vdc
- DC voltage (p.u.)basekVdc
- Base DC voltage (kV)Vdcmax
- maximum DC voltage (p.u.)Vdcmin
- minimum DC voltage (p.u.)Cdc
- DC bus capacitor size (p.u.), (not used in (optimal) power flow)
DC Branch
fbusdc
- from bus number DCtbusdc
- to bus number DCr
- resistance (p.u.)l
- inductance (p.u./s) (not used in (optimal) power flow)c
- total line charging capacity (p.u. * s) (not used in power flow)rateA
- MVA rating ArateB
- MVA rating B (long termrating, not used)rateC
- MVA rating C (long termrating, not used)status
- initial branch status, (1 - in service, 0 - out of service) (not yet implemented)
AC DC converter
busdc_i
- converter bus number (DC bus numbering)busac_i
- converter bus number (AC bus numbering)type_dc
- DC bus type (1 = constant power, 2 = DC slack, 3 = DC voltage droop with DC side active power, 4 = DC voltage droop with AC side active power) (only power flow)type_ac
- AC bus type (1 = PQ, 2 = PV), should be consistent with AC bus (only power flow)P_g
- active power injected in the AC grid (MW)Q_g
- reactive power injected in the AC grid (MVAr)Vtar
- target voltage of converter connected AC bus (p.u.)islcc
- binary indicating LCC converter (islcc = 1 -> LCC)rtf
- transformer resistance (p.u.) (not yet implemented)xtf
- transformer reactance (p.u.) (not yet implemented)transformer
- binary indicating converter transformerbf
- filter susceptance (p.u.) (not yet implemented)filter
- binary indicating converter filterrc
- phase reactor resistance (p.u.) (not yet implemented)xc
- phase reactor reactance (p.u.) (not yet implemented)reactor
- binary indicating converter reactorbasekVac
- converter AC base voltage (kV)Vmmax
- maximum converter voltage magnitude (p.u.)Vmmin
- minimumconverter voltagemagnitude (p.u.)Imax
- maximum converter current (p.u.)status
- converter status (1 = on, 0 = off) (not yet implemented)LossA
- constant loss coefficient (MW)LossB
- linear loss coefficient (kV)LossCrec
- rectifier quadratic loss coefficient (Ω)LossCinv
- inverter quadratic loss coefficient (Ω) (not yet implemented)droop
- DC voltage droop (MW/p.u) (not yet implemented)Pdcset
- voltage droop power set-point (MW) (not yet implemented)Vdcset
- voltage droop voltage set-point (p.u.) (not yet implemented)dVdcset
- voltage droop deadband (p.u.) (optional) (not yet implemented)Pacmax
- Maximum AC active power (MW)Pacmin
- Minimum AC active power (MW)Qacmax
- Maximum AC reactive power (Mvar)Qacmin
- Minimum AC reactive power (Mvar)